logo

商品の詳細

Created with Pixso. ホーム Created with Pixso. 製品 Created with Pixso.
静止型計測装置
Created with Pixso.

3–60 Position Smart Meter Test Equipment

3–60 Position Smart Meter Test Equipment

ブランド名: GENY
モデル番号: YC-1891D
MOQ: 1pcs
価格: 交渉可能
支払条件: L/C、T/T、D/P
供給能力: 1ヶ月あたりの30pcs
詳細情報
起源の場所:
中国
証明:
ISO, CE
出力電流範囲:
1mA -120A (最大230Aまで)
出力電流:
2000VA (最大)
出力電圧電力:
1000VA (最大)
出力電圧範囲:
24Vから288V
パッケージの詳細:
合板ケース
供給の能力:
1ヶ月あたりの30pcs
ハイライト:

3–60 position smart meter tester

,

stationary meter test equipment

,

smart meter test equipment with warranty

製品の説明
3–60 Position Smart Meter Test Equipment
Key Specifications
Output Current Range 1mA -120A (Up to 230A Max)
Output Current Power 2000VA (Max)
Output Voltage Power 1000VA (Max)
Output Voltage Range 24V -288V
Technical Specifications
Power Supply AC220V±10%, 50Hz±2Hz
Ambient Temperature -10°C ... +40°C
Ambient Humidity 35% ... 95%
Output Voltage Range 24V ... 288V
Output Voltage Power 1000VA (Max)
Voltage Resolution 0.01%
Voltage Stability 0.02%/120s
Load Change Rate 0.01%
Voltage Distortion ≤0.3% (Full linear load range)
Output Current Range 1mA ... 120A (Up to 230A Max)
Output Current Power 2000VA (Max)
Current Resolution 0.01%
Current Stability 0.02%/120s
Current Distortion ≤0.3% (Full linear load range)
Continuous Current 100A
Phase Adjustment Range 0° ... 360°
Phase Resolution 0.01°
Frequency Adjustment Range 45Hz ... 65Hz
Frequency Resolution 0.01Hz
Power Output Stability 0.02%/120s
Key Features
  • Active/reactive power & energy metering tests
  • Starting & creep tests with auto-calibration
  • 24 h drift, error, deviation analysis
  • Voltage, frequency, harmonic (2-21), phase-sequence influence tests
  • Non-disconnect testing, open-circuit & short-circuit protection
  • Simultaneous current measurement; optical head auto-scan
  • Electric/manual modes, PC software for data, barcode input
  • 3-60 meter positions, rack scalable
Special Functions
  • Bidirectional active & reactive energy error testing
  • SW-5D precision time-base for daily clock-error measurement
  • Communication protocol test and broadcast time synchronization
  • Constant verification (pulse counting, elapsed-time, or start-stop energy methods)
  • Tariff-switching, demand-interval, and demand-value error testing
  • Register reading and combined register error testing
  • Optional: power-consumption test, tilt-influence test, prepaid-meter test suite
3–60 Position Smart Meter Test Equipment 0 3–60 Position Smart Meter Test Equipment 1 3–60 Position Smart Meter Test Equipment 2