logo

商品の詳細

Created with Pixso. ホーム Created with Pixso. 製品 Created with Pixso.
メーター試験用アクセサリー
Created with Pixso.

HF301 Electric Energy Meter Photoelectric Sampler

HF301 Electric Energy Meter Photoelectric Sampler

ブランド名: GENY
モデル番号: HF301
MOQ: 1
価格: negotiate rates
支払条件: T/T、L/C、D/P、T/T
供給能力: 100個/1ヶ月
詳細情報
起源の場所:
中国
証明:
ISO, CE
タイプ:
メーター試験用アクセサリー
動作電圧:
DC4.5~6V
消費電力:
≤ 0.35 W (無負荷)
サンプリング距離:
1.0~2.0mm
出力電流:
3~5mA
サンプリング周波数:
200のHz
パッケージの詳細:
合板ケース
供給の能力:
100個/1ヶ月
ハイライト:

HF301 electric energy meter

,

photoelectric sampler meter

,

meter testing accessory with warranty

製品の説明
HF301 Electric Energy Meter Photoelectric Sampler
Main Features
  • Compact size, stable and reliable operation, suitable for use with electric energy meter calibration devices.
  • Uses imported receiver components with strong anti-interference capability.
  • High sampling/reception frequency up to 200 Hz, fully meeting the requirements of various meters.
Operating Instructions
  • When collecting signals from a mechanical electric energy meter, turn on the red switch on the controller and align the sampler with the surface of the mechanical meter so that the light beam points at the meter's rotating disc.
  • Connect the power. The green LED will stay on. Adjust the potentiometer until the red LED for pulse output lights up; then turn the potentiometer in the opposite direction until, when there is no black mark on the meter's disc, the red signal LED just turns off. When the black mark arrives, the signal indicator LED should light up (indicating signal output). At this point, the adjustment is complete.
  • When receiving the LED pulse signal indicator from an electronic energy meter, press the red button on the controller to turn off the LED of the emitting sampling component. Align the center receiving tube with the meter's LED pulse signal indicator. (Follow the same steps as in item 2 thereafter.)
Technical Specifications
Parameter Value
Operating voltage DC 4.5-6 V
Operating current ≤ 50 mA (measured at 5 V supply)
Power consumption ≤ 0.35 W (no load)
Sampling distance 1.0-2.0 mm
Output signal High level ≥ 4.5 V (no black mark), Low level ≤ 0.2 V (with black mark)
Output current 3-5 mA
Anti-interference Debounce tolerance ≤ 2.0 mm
Sampling frequency 200 Hz
HF301 Electric Energy Meter Photoelectric Sampler 0