Three-Phase Stationary Power Source for Power Utilities and Meter Manufacturers
High-Accuracy Three-Phase Stationary Power Source
Professional-grade power source designed specifically for power utilities and meter manufacturers, delivering exceptional accuracy and reliability for testing applications.
Key Features
  • High accuracy with excellent long-term output stability
  • RS232 communication interface supporting automated operation
  • Optional built-in keyboard for convenient manual operation
  • Harmonics from 2nd to 21st order freely programmable in amplitude and phase angle
  • Rugged aluminum alloy enclosure: lightweight, high strength, and corrosion-resistant
  • User-friendly PC control software for easy operation and system integration
  • Comprehensive protection functions including overload, short-circuit voltage, and open-circuit current protection
Technical Specifications
Voltage Output
Parameter Specification
Test Voltage (Phase-Neutral) 3 × (24 V - 288 V) or customized
Voltage Output Power 3 × 100 VA, 3 × 250 VA, 3 × 500 VA, 3 × 1000 VA
Resolution Better than 0.01% of full-scale range
Setting Accuracy Better than 0.05% of final range value
Stability Better than 0.005%/h (integration time: 150 s)
Load Regulation (0 to Max Load) < 0.01%
Distortion Factor < 0.3% (linear resistive load)
Harmonics 2nd - 21st, freely programmable
Current Output
Parameter Specification
Test Current Range 3 × (1 mA - 100 A)
Current Output Power 3 × 150 VA, 3 × 350 VA, 3 × 750 VA, 3 × 1500 VA
Resolution Better than 0.01% of full-scale range
Setting Accuracy Better than 0.05% of final range value
Stability Better than 0.005%/h (integration time: 150 s)
Load Regulation (0 to Max Load) < 0.01%
Distortion Factor < 0.3% (linear resistive load)
Harmonics 2nd - 21st, freely programmable